Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cardiovasc Surg (Torino) ; 55(2 Suppl 1): 159-68, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24796909

RESUMO

For more than half a century ischemic spinal cord injury (SCI) and consecutively permanent paraplegia remained the most devastating complication after open and endovascular thoracoabdominal aortic aneurysm (TAAA) repair. Various neuroprotective strategies (e.g., motor-/somatosensory evoked potential monitoring and cerebrospinal fluid drainage) used as adjuncts have lowered the SCI; maybe most importantly, the modern collateral network (CN) has begun to replace the classic understanding of spinal cord blood supply implying several consequences. Reliable non-invasive tools to monitor cord perfusion to detect imminent spinal cord malperfusion, ischemia and forthcoming neurologic injury (particularly early postoperatively) is not available, neither is a reliable strategy to prevent ischemic injury during distal circulatory arrest and after segmental artery occlusion. Currently, two promising new concepts--potentially advancing spinal protection in open and endovascular TAAA repair--address these issues: 1) non-invasive real-time monitoring of the paraspinous CN-oxygenation via near-infrared spectroscopy (NIRS) as an alternative to the demanding direct neuromonitoring; and 2) preconditioning of the CN as minimally invasive, endovascular "first stage" to increase the resilience of spinal cord perfusion prior to definite aortic repair. This article illustrates both concepts discussing: 1) the clinical application of thoracic and lumbar collateral NIRS monitoring to indirectly detect spinal cord hypoperfusion; and 2) minimally invasive selective segmental artery coil-embolization (MISACE) for (arteriogenic) preconditioning of the CN prior to extensive open or endovascular staged TAAA repair.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Isquemia do Cordão Espinal/etiologia , Medula Espinal/irrigação sanguínea , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/fisiopatologia , Circulação Colateral , Embolização Terapêutica , Hemodinâmica , Humanos , Monitorização Intraoperatória/métodos , Paraplegia/diagnóstico , Paraplegia/etiologia , Paraplegia/prevenção & controle , Fluxo Sanguíneo Regional , Fatores de Risco , Espectroscopia de Luz Próxima ao Infravermelho , Isquemia do Cordão Espinal/diagnóstico , Isquemia do Cordão Espinal/prevenção & controle , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...